Note to users. If you're seeing this message, it means that your browser cannot find this page's style/presentation instructions -- or possibly that you are using a browser that does not support current Web standards. Find out more about why this message is appearing, and what you can do to make your experience of our site the best it can be.

Site Tools

  • AAAS
  • Subscribe
  • Feedback

Site Search

Search Advanced

Science 10 July 1987:
Vol. 237. no. 4811, pp. 164 - 168
DOI: 10.1126/science.3496662

Articles

Science, Vol 237, Issue 4811, 164-168
Copyright © 1987 by American Association for the Advancement of Science


articles

Laser-stimulated luminescence used to measure x-ray diffraction of a contracting striated muscle

Y Amemiya, K Wakabayashi, H Tanaka, Y Ueno, and J Miyahara

An integrating x-ray area detector that operates on the basis of laser-stimulated luminescence was used in a diffraction study of muscle contraction. The area detector has a dynamic range of 1 to 10(5), a sensitivity about 60 times greater with approximately 1/300 as much fog background as x-ray film. It is erasable and reusable but, like film, can integrate at a practically unlimited counting rate. The high sensitivity and wide dynamic range of the detector resulted in a sufficient reduction in the exposure time to make possible the recording of a clear x-ray diffraction pattern, with up to 2.0-nanometer axial spacing, from a contracting frog skeletal muscle in as little as 10 seconds with synchrotron radiation. During the isometric contraction of the muscle, most of the actin diffraction lines increased in intensity without noticeable changes in their peak positions. Changes also occurred in diffraction intensities from the myosin heads. The results indicate that during contraction the structure of the actin filaments differs from that in the rigor state, suggesting a possible structural change in the actin subunits themselves; the myosin heads during contraction retain the axial periodicity of the myosin filament and become aligned in a more perpendicular manner to the actin filaments.


THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES:
The Untranslated Region of {micro}-Opioid Receptor mRNA Contributes to Reduced Opioid Sensitivity in CXBK Mice.
K. Ikeda, T. Kobayashi, T. Ichikawa, T. Kumanishi, H. Niki, and R. Yano (2001)
J. Neurosci. 21, 1334-1339
   Abstract »    Full Text »    PDF »
Dynamic electron microscopy of ATP-induced myosin head movement in living muscle thick filaments.
H. Sugi, T. Akimoto, K. Sutoh, S. Chaen, N. Oishi, and S. Suzuki (1997)
PNAS 94, 4378-4382
   Abstract »    Full Text »    PDF »
Time-resolved x-ray diffraction of biological materials.
S. Gruner (1987)
Science 238, 305-312
   Abstract »    PDF »
New Opportunities in Synchrotron X-ray Crystallography.
C. T. PREWITT, P. COPPENS, J. C. PHILLIPS, and L. W. FINGER (1987)
Science 238, 312-319
   Abstract »    PDF »