Note to users. If you're seeing this message, it means that your browser cannot find this page's style/presentation instructions -- or possibly that you are using a browser that does not support current Web standards. Find out more about why this message is appearing, and what you can do to make your experience of our site the best it can be.


Science 18 August 1967:
Vol. 157. no. 3790, pp. 825 - 827
DOI: 10.1126/science.157.3790.825

Articles

Flow Characteristics of Human Erythrocytes through Polycarbonate Sieves

Magnus I. Gregersen 1, Cyrus A. Bryant 1, Walter E. Hammerle 1, Shunichi Usami 1, and Shu Chien 1

1 Laboratory of Hemorheology and Department of Physiology, Columbia University College of Physicians and Surgeons, New York, New York

We used polycarbonate sieves with uniform cylindrical pores (2.4 to 6.8 microns in diameter) to filter suspensions of human erythrocytes (mean major diameter is 7.2 microns) in Eagle-albumin solution. With 6.8-micron sieves the pressure-flow curves are convexed to the pressure-axis at low pressures and become linear with high pressures. With 4.5-micron sieves, however, the pressure-flow relationship is linear throughout the range of study. In both types of sieves, flow rate is reduced progressively with increasing concentration of red blood cells (RBC) over a range of 0.5 to 95 percent. The resistance to flow of RBC suspensions is higher in 4.5-micron than in 6.8-micron pores. With filter pore diameters of 3.0 microns or more, the RBC concentration in the filtrate was 100 percent of that in the solution being filtered, but only 70 percent with 2.4-micron pores. The observed critical pore diameter for 100 percent cell transmission agrees with theoretical calculation based on the assumption that the RBC membrane is deformable but nonextensible. The importance of cell deformation in the passage of RBC's through small pores is shown by the inability of RBC hardened in acetaldehyde to pass pores with 6.8-micron diameter.


THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES:
Peculiar flow patterns of RBCs suspended in viscous fluids and perfused through a narrow tube (25 {micro}m).
H. Sakai, A. Sato, N. Okuda, S. Takeoka, N. Maeda, and E. Tsuchida (2009)
Am J Physiol Heart Circ Physiol 297, H583-H589
   Abstract »    Full Text »    PDF »
Sickle cell vasoocclusion and rescue in a microfluidic device.
J. M. Higgins, D. T. Eddington, S. N. Bhatia, and L. Mahadevan (2007)
PNAS 104, 20496-20500
   Abstract »    Full Text »    PDF »
Red blood cell trauma during cardiopulmonary bypass: narrow pore filterability versus free haemoglobin.
S. Svenmarker, E. Jansson, H. Stenlund, and K. G. Engstrom (2000)
Perfusion 15, 33-40
   Abstract »    PDF »
Red Cell Deformability Changes as a Prognostic Indicator of Postoperative Morbidity in Cardiac Surgery Using Cariopulmonary Bypass.
A. Belboul, N. Al-Kahaja, P. Bergman, D. Roberts, and G. William-Olsson (1991)
Vascular and Endovascular Surgery 25, 476-487
   Abstract »    PDF »
Rheological Aspects of Sickle Cell Disease.
P. P. Klug, L. S. Lessin, and P. Radice (1974)
Arch Intern Med 133, 577-590
   Abstract »    PDF »
Prostaglandins in Hematology.
J. E. Allen and C. R. Valeri (1974)
Arch Intern Med 133, 86-96
   Abstract »    PDF »
Particle Track Etching: Diverse technological uses range from virus identification to uranium exploration.
R. L. Fleischer, R. L. Fleischer, H. W. Alter, S. C. Furman, P. B. Price, and R. M. Walker (1972)
Science 178, 255-263
   PDF »
Erythrocyte Adherence and Diapedesis: Some Aspects of a Possible Mechanism Based On Vital and Electron Microscopic Observations.
R. Skalak and R. Ekholm (1970)
Angiology 21, 224-239
   PDF »
Deformation of Red Blood Cells in Capillaries.
R. Skalak and P I Branemark (1969)
Science 164, 717-719
   Abstract »    PDF »
Blood Viscosity: Influence of Erythrocyte Deformation.
S. Chien, S. Usami, R. J. Dellenback, and M. I. Gregersen (1967)
Science 157, 827-829
   Abstract »    PDF »



To Advertise     Find Products


Science. ISSN 0036-8075 (print), 1095-9203 (online)