Science 3 June 1960: Vol. 131. no. 3414, pp. 1668 - 1669 DOI: 10.1126/science.131.3414.1668
|
|
Articles
Automatic Tonometer with Exact Theory: Various Biological Applications
R. Stuart MacKay 1,
Elwin Marg 1, and
Raymond Oechsli 1
1 School of Optometry, University of California, Berkeley
Methods for externally measuring pressure within body cavities exist. In tonometer form they are fast and gentle not requiring anesthetics for the cornea of the human eye. Readings are accurate and independent of tissue tension, corneal stiffness, astigmatic curvatures, and surface tension. There are also separate indications of corneal rigidity and relaxation, and tonographic fluid expression. Other applications include monitoring blood pressure, uterine contractions, and infant intracranial pressure.
THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES:
- The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry.
- P-A Tonnu, T Ho, T Newson, A El Sheikh, K Sharma, E White, C Bunce, and D Garway-Heath (2005)
Br J Ophthalmol
89, 851-854
| Abstract »
| Full Text »
| PDF »
- The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology.
- A C Browning, A Bhan, A P Rotchford, S Shah, and H S Dua (2004)
Br J Ophthalmol
88, 1395-1399
| Abstract »
| Full Text »
| PDF »
- Tono-Pen determination of intraocular pressure in patients with band keratopathy or glued cornea.
- A. Azuara-Blanco, T. K Bhojani, A. R Sarhan, C T Pillai, and H. S Dua (1998)
Br J Ophthalmol
82, 634-636
| Abstract »
| Full Text »
- Clinical Evaluation of the Cavitron Biotronics Tonometer.
- K. Miller, G. E. Sanborn, and L. W. Jennings (1988)
Arch Ophthalmol
106, 1210-1213
| Abstract »
| PDF »
- The Tono-Pen: A Manometric and Clinical Study.
- W. A. Boothe, D. A. Lee, W. C. Panek, and T. H. Pettit (1988)
Arch Ophthalmol
106, 1214-1217
| Abstract »
| PDF »
- Comparison of the Tono-Pen to the Goldmann Applanation Tonometer.
- R. E. P. Frenkel, Y. J. Hong, and D. H. Shin (1988)
Arch Ophthalmol
106, 750-753
| Abstract »
| PDF »
- Prevention of Infection During Tonometry.
- R. M. WOOD (1962)
Arch Ophthalmol
68, 202-218
| Abstract »
| PDF »
- Glaucoma.
- H. I. McGARRY (1961)
Arch Ophthalmol
66, 871-895
| PDF »
- Corneal Bending and Buckling in Tonometry.
- E. MARG, R. S. MACKAY, and R. CECHSLI (1961)
Arch Ophthalmol
65, 67-74
| Abstract »
| PDF »
|
|