Note to users. If you're seeing this message, it means that your browser cannot find this page's style/presentation instructions -- or possibly that you are using a browser that does not support current Web standards. Find out more about why this message is appearing, and what you can do to make your experience of our site the best it can be.


Science 26 March 1976:
Vol. 191. no. 4233, p. 1261
DOI: 10.1126/science.191.4233.1261

Articles

Vapor Pressure of Water at Its Triple Point: Highly Accurate Value

L. A. GUILDNER 1, D. P. JOHNSON 1, and F. E. JONES 1

1 Institute for Basic Standards, National Bureau of Standards, Washington, D.C. 20234

The vapor pressure of water at its triple point was measured with greatly increased accuracy. The triple point was realized with newly designed equipment that enhanced the stability of the pressure and permitted any air released from solution to be removed by pumping. A diaphragm pressure transducer separated the water vapor from the helium used to transmit the pressure to the manometer. The pressure was measured with the National Bureau of Standards precision mercury manometer. The vapor pressure at the triple point was found to be 611.657 pascals with random uncertainties at the 99 percent confidence level of ± 0.010 pascal. The systematic errors are estimated to be relatively insignificant.