Cell Microfluorometry: A Method for Rapid Fluorescence Measurement
M. A. Van Dilla 1,
T. T. Truiullo 1,
P. F. Mullaney 1, and
J. R. Coultex 1
1 Biomedical Research Group, Los Alamos Scientific Laboratory, University of California, Los Alamos, New Mexico 87544
A high-speed flow system for quantitative determination of fluoresence of cells containing fluorochrome has been developed. Feulgen-DNA distributions in populations of tissue culture cells and human leukocytes havebeen measured at a rate of 104 to 105 cells per minute and compare well with results of other independent methods.
THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES:
- Quantitative morphometric measurements using site selective image cytometry of intact tissue.
- H.-S. Kwon, Y. S. Nam, D. M Wiktor-Brown, B. P Engelward, and P. T.C So (2009)
J R Soc Interface
6, S45-S57
| Abstract »
| Full Text »
| PDF »
- Plant DNA Flow Cytometry and Estimation of Nuclear Genome Size.
- J. DOLEZEL and J. BARTOS (2005)
Ann. Bot.
95, 99-110
| Abstract »
| Full Text »
| PDF »
- Borna Disease Virus Nucleoprotein Interacts with the Cdc2-Cyclin B1 Complex.
- O. Planz, S. Pleschka, K. Oesterle, F. Berberich-Siebelt, C. Ehrhardt, L. Stitz, and S. Ludwig (2003)
J. Virol.
77, 11186-11192
| Abstract »
| Full Text »
| PDF »
- Chromosomal Variations Within Aneuploid Cancer Lines.
- T. Isaka, A. L. Nestor, T. Takada, and D. C. Allison (2003)
J. Histochem. Cytochem.
51, 1343-1353
| Abstract »
| Full Text »
| PDF »
- Correlated measurements of DNA, RNA, and protein in individual cells by flow cytometry.
- H. Crissman, Z Darzynkiewicz, R. Tobey, and J. Steinkamp (1985)
Science
228, 1321-1324
| Abstract »
| PDF »
- Flow cytometry: a high-resolution instrument for everyone.
- H. Steen and T Lindmo (1979)
Science
204, 403-404
| Abstract »
| PDF »
- Quantitative single cell analysis and sorting.
- P. Horan and L. Wheeless Jr (1977)
Science
198, 149-157
| PDF »
- Cell-Cycle Analysis in 20 Minutes.
- H. A. Crissman and R. A. Tobey (1974)
Science
184, 1297-1298
| Abstract »
| PDF »
- DNA Constancy in Heteroploidy and the Stem Line Theory of Tumors.
- P. M. Kraemer, D. F. Petersen, and M. A. Van Dilla (1971)
Science
174, 714-717
| Abstract »
| PDF »
- Cell Sorting: Automated Separation of Mammalian Cells as a Function of Intracellular Fluorescence.
- H. R. Hulett, W. A. Bonner, J. Barrett, and L. A. Herzenberg (1969)
Science
166, 747-749
| Abstract »
| PDF »
|
|